1171. Photo
Cell Characteristics Apparatus
Specifications:
A variable D. C. Power Supply is fitted with two meters to read
D. C. voltage applied to the Photo Tube, and second meter is
provided to read the current. Complete circuit diagram is engraved
on the front panel. |
|
|
|
1172. Photo Cell
Selenium characteristic curve apparatus. |
|
|
|
1173. Plank's Constant
Apparatus
The Instrument is provided with complete circuit diagram for
estimation of plank constant. Power supply is built in provided with
Micro ammeter and voltmeter to read the current and voltage. Set of
three filters are provided. Photocell vaccum tube 868 or its
equivalent is used. Provided with D. C. Amplifier. Terminals are
provided for connecting 6.3 volts Bell or buzzer. |
|
|
|
1174. Thyratron Characteristics' Apparatus
To study the ionisation potential of thyraton valve (Control
characteristic) it consists of three meters to read Anode voltage,
Anode current and Grid Bias. Provided with two power supplies of its
own, with circuit diagram and instruction manual. Graph is ploted
between Grid Bias and Anode voltage. |
|
|
|
Battery Eliminators
These can be used with AC supply in place of DC Batteries.
1175. Battery Eliminator
Output 2,4,6,8,10,12V, DC, 1 Amp. |
|
|
|
1176. Battery
Eliminator
Output 2, 4, 6, 8, 10 12V DC, 2 Amps. |
|
|
|
1177. Battery
Eliminator
Output 2, 4, 6, 8, 10, 12 V DC, 3 Amps. |
|
|
|
1178. Battery
Eliminator
Output 2, 4, 6V., DC 3 Amps. |
|
|
1179. Battery Eliminator
Output 2, 4, 6,8, 10, 12 V. DC, 4 Amps. |
|
|
|
1180. V. T.
V. M. (Vacuum Tube Voltmeter)
Specification:
A.C. Voltage:0-1.5, 5,15, 50,150,500, 1500 V.
D.C. Voltage: 0-1.5, 5,15, 50,150, 500,1500 V.
Positive or negative by selecting the position of the switch.
Resistance : 0-1, 10K, 100K, 1 M, 10M, 100M.
1000 meg ohms.
d BM : Alternating current of the unit 1 m W represents 0 dB. d Bm
has two ranges on direct current 1.5 V and 15 V and when the
terminating impedence is 600 ohms these ranges are -20 ± 6dB and 5±
24 dB.
terminating impedence is 600 ohms these ranges are -20 ± 6dB and 5±
24 dB.
Calibration Accuracy : A. C. Voltage ± 2 % on all ranges.
D. C. Voltage : ± 2% on all ranges.
Resistance within ± 3% on all ranges.
d BM within ± 0.5 dB.
Frequency Response : : Within range of 30c/s to 5Mc/s flat.
Input Impedence : D. C. for voltage: 11 M ohms on all ranges for A.
C. Voltage: 5M ohms in parallel with 25 p F. |
|
|
| |
|
|