Model
: DTM-1501
DIGITAL CAPACITANCE METER
• Display : 3-1/2Digits, 1999 Counts
• Measure : 0.1pF to 20mF
• Range : 0 200pF / 2000pF / 20nF / 200nF / 2uF / 20uF /
200nF / 2uF / 20uF / 200uF / 2000uF / 20mF
• Accuracy : ±0.5%
• Zero Adjustment
• With Holster |
|
|
|
Model
: DTM-1500
DIGITAL CAPACITANCE
• Display : 3-1/2Digits, 1999 Counts
• Measure : 0.1pF to 20mF
• Range : 0 200pF / 2000pF / 20nF / 200nF / 2uF / 20uF /
200uF / 2000uF / 20mF
• Accuracy : ±0.5%
• Zero Adjustment
• With Holster |
|
|
|
Model
: M-300
ANALOGUE CLAMP TESTER
• Complies with Class II, over voltage CAT.II600V of the
IEC1010-1 (EN61010-1) standards.
• DC Voltage : 0 – 75V
• Accuracy : ±3% of full scale
• AC Voltage : 0 – 150/300/750V
• Accuracy : ±3% of full scale
• AC Current : 0 – 6/15/60/150/300A
• Accuracy : ±3% of full scale
• Resistance : 0 – 2kW/200kW
• Accuracy : ± ±3% of full scale
• Temperature : -20°C ~ 150°C
• Accuracy : within ±3% of arc
• Jaw Size : 34mm Dia.
• Pointer Lock facility |
|
|
|
Model
: M-600
ANALOGUE CLAMP TESTER
• Complies with Class II, over voltage CAT.II600V of the
IEC1010-1 (EN61010-1) standards.
• DC Voltage : 0 – 75V
• Accuracy : ±3% of full scale
• AC Voltage : 0 – 150/300/750V
• Accuracy : ±3% of full scale
• AC Current : 0 – 6/15/60/150/600A
• Accuracy : ±3% of full scale
• Resistance : 0 – 2kW/200kW
• Accuracy : ± ±3% of full scale
• Temperature : -20°C ~ 150°C
• Accuracy : within ±3% of arc
• Jaw Size : 34mm Dia.
• Pointer Lock facility |
|
|
Model : DT-125
DIGITAL CLAMP TESTER
• Display : 3-1/2 Digits 1999 Counts
Backlit LCD
• DC Voltage : 0 – 200mV ~ 600V
• Accuracy : ±0.5%
• AC Voltage : 0 – 200mV ~ 600V
• Accuracy : ±1.5%
• AC Current : 0 – 2A ~ 400A
• Accuracy : ±2%
• Resistance : 0 – 200W
~ 20MW
• Accuracy : ± 1%
• Jaw Size : 23mm Dia.
• Diode Test, Audible Continuity, Data Hold, Maximum Hold
and Auto Power Off. |
|
|
Model : M-2020
DIGITAL CLAMP TESTER
• Display : 3-1/2 Digits 3200 Counts
• DC Voltage : 0 – 300mV ~ 500V
• Accuracy : ±1.3%
• AC Voltage : 0 – 3V ~ 500V
• Accuracy : ±2.3%
• AC Current : 0 – 30A ~ 300A
• Accuracy : ±2%
• Jaw Size : 40mm Dia.
• Data Hold, Auto ranging and Auto Power Off. |
|
|
Model : 14
DIGITAL TEMPERATURE CALIBRATOR
• 5-1/2 Digits Large Display
• Microprocessor Based
• High Accuracy of ± 0.02%
• Output data
• Voltage : -10mV – 1.1V
• Accuracy : ±0.02%
• Resistance : 0 - 250W (±0.02%)
• Thermocouple : R,S,B,E,J,T,N
• Thermo-resistance :
Pt100 : -200 – 850°C
Cu50 : -50 – 150°C
• Input data :
• Voltage : 0 - ±450mV
• Accuracy : 0.02%
• Resistance : 0 - 450W (±0.02%)
• Thermocouple : R,S,B,E,K,J,T,N
Pt100 : -200 – 850°C
Cu50 : -50 – 150°C |
|
|
Model : 15
VOLTAGE/mA CALIBRATOR
• 5-1/2 Digits Large Display
• Microprocessor Based
• High Accuracy of ± 0.02%
• Output data
• Voltage : 0V – 11V (±0.02%)
• Current : 0 – 22mA (±0.02%)
• Sinking current : 0 – 22mA (±0.02%)
• Loop Power : 24V
• Input data :
• Voltage : 0 – 11V (±0.02%)
• Current : 0 – 22mA (±0.02%)
• Loop Power : 24V (±0.02%) |
|
|
|
<<BACK
|
NEXT >> |
|
Page |
1 -
2 -
3 -
4
-
5 -
6 -
7 -
8 |
|